DG multi - stage boiler feed pump operation and use of emergency precautions

DG multi-stage boiler feed pump suitable for conveying the temperature below 110 ° C water or physical and chemical properties similar to the water-free non-corrosive other liquids, widely used in industrial and mining enterprises and the boiler water supply and urban life water supply. DG-type multi-stage pump is particularly suitable for boiler feed water, can also be widely used in pressure vessel water supply, hot water circulation, high-rise building water supply, farmland irrigation , fire pressurization, hydraulic washing, food, brewing, medicine, chemicals, aquaculture, Environmental protection and other industries. For the safety of the operator, DG-type horizontal multi-stage boiler feed pump start operation, it should be noted that the boiler feed pump start operation precautions;       1, DG horizontal multi-stage boiler feed pump operation Note:         1) Before starting the pump, rotate the rotor and check whether the rotor is flexib...

Causes and Control of Boiler Feed Pump Noise

Boiler pump noise is a reflection of the characteristics of the working state of the pump, the Boiler pump noise, mainly by the various parts of the pump parts or pump flow of media generated. Reduce the noise, it is necessary to carefully analyze the noise generated by the sound source to improve the structure of the sound source or medium motion. 1, the main causes of noise in the following areas:         1) mechanical noise         Multi-stage centrifugal pump with the guide vane, rigid or guide the population at the cross-sectional area and the entrance edge thickness with unreasonable, it may cause a larger vibration generated by the pump noise.         Second, the pump rotor parts and non-rotating between the pump, due to contact friction, will also produce higher frequency noise.         Due to the external structure of the boiler feed water pump and the installation of the problems arising fro...

What is the role of boiler multi-stage pump mouth ring?

Boiler multi-stage pump ring (also known as sealing ring), the general number of water pump and the number of rings is the same, that is, a 5-level pump, then there are five rings, a mouth ring, 4 mouth rings.  Boiler multi-stage pump port ring role:         1, the boiler multi-stage pump ring is the role of the impeller and the pump shell to form a narrow, twists and turns of the channel, to increase the flow resistance of the medium to achieve the purpose of reducing media leakage. Boiler multi-stage pump port ring also set up to protect the main parts of the pump from the role of wear and tear, the ring ring wear, you can repair or replace the new ring, to restore the normal assembly gap, so economical and easy maintenance.         2, the gap between the mouth of the General Assembly will be the efficiency of the use of low pump, pump pressurized fluid will be too much from the pump outlet area along the impeller and the mouth of the ...

Feedwater pump recirculation multi - stage throttle device installation standard

Throttle device is used to measure the flow, its working principle is as follows: in the pipeline with a cross-section changes in the orifice or nozzle and other throttle, when the fluid flow through the throttle due to shrinkage, Resulting in static pressure difference, the use of pressure and the relationship between the flow rate can be further measured flow. For non-calibrated throttle devices, as long as it is geometrically similar and kinetic to the throttle device that has been fully experimentally calibrated, the static pressure difference between the front and rear of the throttle can be considered under the known parameters There is a definite numerical relationship between the flow of the fluid flowing through the fluid. So you can measure the flow through the pressure difference.    The correctness and reliability of the flowmeter installation is important for ensuring that the differential pressure signal output from the throttle device is accurately transmitted ...

The Function and Principle of Inlet Filter for Feed Water Pump

Feed pump inlet filter, also known as condensate pump inlet filter, used in the thermal power steam boiler condensing tower condensate pump inlet, used to eliminate impurities in the media to protect the normal use of equipment and valves. Feed water pump import filter use:         Mainly applicable to a variety of different filtration, dust and separation requirements for petroleum, chemical, mineral, food, pharmaceutical, painting and other industries filter. Painting filter material can be divided into two kinds of metal and plastic, filter installed in the gun on the location of different types, generally stainless steel and nylon material is better.       Feed pump inlet filter by process points:         1, multi-layer spot welding filter.         2, multi-layer package edge filter.       Stainless steel feed pump inlet filter mesh by shape points:         Rectangul...

Stainless steel sewage pump noise reasons

Stainless steel sewage pump is designed according to national standards, suitable for long-term delivery of any concentration of strong acid, alkali, salt, strong oxidants and other corrosive media, the shell, the main pipe, outlet and over-flow parts all plastic alloy molding Sintering made of the pump part of the host all placed in the liquid, with strong corrosion resistance, good wear resistance, high mechanical strength, no oxidation, non-toxic decomposition characteristics. Stainless steel liquid sewage pump and medium contact with the parts, the Department of polyvinyl butyral modified phenolic glass fiber, high temperature molding of phenolic glass steel parts, connecting pipe, the liquid pipe semi-dry rolling system Into the phenolic glass pipe, the impeller sleeve assembly are used phenolic cement and liquid pump pump shaft stick into one, the liquid under the assembly are used phenolic cement mortar, into the liquid without metal and medium contact, corrosion resistance Abs...

Mechanical seal of YW submerged non-clogging sewage pump

YW submerged non-clogging sewage pump is based on the combination of advanced technology at home and abroad, the use of liquid pump characteristics and the successful development of a new generation of liquid sewage pump products, with significant energy saving effect, anti-winding, no clogging and other characteristics, in the row To send solid particles and long fiber garbage has a unique effect. It is a vertical liquid structure, working in the pump immersed in water, the liquid depth of up to 0.5 ~ 5m, and the use of a unique single leaf or double blade impeller structure, can effectively through the pump diameter 5 times the fiber material and diameter For the diameter of 50% of the solid particles. YW submerged non-clogging sewage pump hydraulic performance advanced, mature, the product tested by the performance indicators have reached the relevant standards, products on the market with its unique efficacy, reliable performance, stable quality by the majority of users welcome an...